Documentation >
MAC-PAC Reference and Help >
Technical Support >
Key Concepts and Procedures >
Operation Procedures >
End Online Processing
End Online Processing
The procedure to end online processing consists of the following steps:
· Cancel asynchronous monitors.
· Check for failed online transactions.
· Back up master files.
· Change journal receiver.
· Back up receiver.
The Initiate/Cancel Monitors Menu is used to cancel any or all of the asynchronous monitors. Multi-transaction monitors are terminated by sending a SHUTDOWN message to the message queue (the JIT Async Monitor may receive a SHUTDOWN or SHUTDOWNNIGHT message). Single-transaction monitors are terminated by writing a special end-of-file record (**EOF$ in the Order Number field) to the corresponding transaction file. For more detail on these monitors, see the appropriate program descriptions in the appropriate program documentation manual.
Note: Only monitors for the modules installed will be displayed on the Initiate/Cancel Menu. For example, if Just-In-Time is not installed the JIT Async Monitor (JTASYNCMON) would not be displayed. Likewise if SYNCHRO is not installed, the SYNCHRO Report Request (GAASYNCMON), SYNCHRO INVOICE Message Extraction (GAIITMON), and SYNCHRO Shipping/Billing (GASBUMON) monitors would not be displayed on the menu.
The Recovery Management Menu is used to perform the remaining steps to end online processing. The required user procedures are described below. They are illustrated below.
End Online Processing.
How to End Online Processing
Display Initiate/Cancel
|
Step 1.
|
Select the Initiate/Cancel Monitors Menu option on the System Processing Menu. The Initiate/Cancel Monitors Menu is displayed. A sample of this screen is shown below.
|
INITIATE/CANCEL MONITORS
Main Manufacturing MSQ A MON2:MSGQ for Bar-Code A
MON3:MOMNT; LR's; CR's A MON4: Overflow A
Shipping/Billing Update A Just-In-Time
Consolidated Billing Update Electronic Data Collection
Immediate Picker Print A Purchasing A
Immediate Invoice Print Purchase Order Generation
Immediate BOL Print A EDI PO Ackn Update
Immediate SO Ackn Print EDI PO Receipts Update
Immediate Quote Ackn Print EDI Sales Order Generation
Immediate RMA Ackn Print Synchro/Shipping & Billing
Stock Loc Reservation Synchro/Invoice Transmitter
Sales Analysis Post Synchro/Report Requests
Control Total Update A Load Consolidation Update
Synchro/Customer KANBAN Business Process Manager
Manufacturing Configuration A
Option: 1 - Initiate
2 - Cancel
3 - JIT Night Cancel
F3=Exit F5=Refresh
|
Initiate/Cancel Monitors Screen.
Cancel Monitor(s)
|
Step 2.
|
To the right of each monitor is a status field and an input field. An A appears in the status field of any monitor that is active. Otherwise, this field will be blank.
Enter a 2 in the input field to the right of each active monitor that is to be canceled, and press the ENTER key. The A will remain in the status field until the request has been processed. At that point, the field will become blank after the ENTER key has been pressed.
|
|
|
For the JIT Async Monitor (JTASYNCMON) you have two canceling options. Use option 2 to cancel immediately as described above. Use option 3 (JIT Night Cancel) to cancel the monitor only after all submitted async jobs have completed. This option should be used before any batch jobs are run to insure all automatically generated flow receipts are processed.
|
Return
|
Step 3.
|
Press F3-Exit to return to the System Processing Menu.
|
Display Recovery Management Menu
|
Step 4.
|
Select the Recovery Management option on the System Processing Menu. The Recovery Management Menu is displayed. A sample of this screen is shown below.
|
RECOVERY MANAGEMENT MENU
Select one of the following:
System Recovery Journal/Journal Receiver Management
1. On-line Rollback 10. Journal Physical Files
2. Off-line Rollback 11. Create Journal Receiver
3. Rollforward 12. Create Journal
13. Change Journal Receiver
End Processing 14. Display Journal Attributes
4. On-line
5. Off-line Other Options
83. Display Messages
File Backup/Restore 85. Work With Submitted Jobs
6. Backup Data Library 89. Return
7. Restore Data Library 90. Signoff
8. Backup Receiver
9. Restore Receiver
Selection or command
===>
F3=Exit F4=Prompt F9=Retrieve
|
Recovery Management Menu.
Check for Failed Online
|
Step 5.
|
Select the Online option on the Transactions Recovery Management Menu. If no online transactions have failed, the Recovery Management Menu is redisplayed with the Option field blank. If any online transactions have failed, the Failed Online Transactions List screen is displayed. See the Recovery Management section of this manual for a description of this screen and for the necessary recovery procedures.
|
Back Up Master Files
|
Step 6.
|
The frequency with which master files are backed up must be determined at each site. A suggested strategy is to back up the master files weekly, either at the beginning or the end of the work week. To back up all master files, select the Back Up Masters option on the Recovery Management Menu.
|
Note: If files are being reorganized, master files must be backed up after the reorganization jobs have completed and before any further jobs are executed. Otherwise, rollback recovery cannot be used to recover from a subsequent system failure.
Change Journal Receiver
|
Step 7.
|
Select the Change Journal Receiver option on the Recovery Management Menu. The system automatically generates a new receiver. The journal receiver must be changed before batch processing is started.
|
Display Journal Attributes
|
Step 8.
|
Select the Display Journal Attributes option on the Recovery Management Menu. The attributes for the journal receivers are displayed. The system-assigned name of any receiver that is to be backed up should be noted.
|
Back Up Receiver
|
Step 9.
|
The journal receiver should be backed up whenever the journal receiver is changed. To back up a journal receiver, select the Back Up Receiver option on the Recovery Management Menu. The Journal Receiver Backup screen is displayed. A sample of this screen is found in the Recovery Management section of this manual. Enter the name of each journal receiver that is to be backed up and press the ENTER key. The Recovery Management Menu is redisplayed.
|
Return
|
Step 10.
|
Press F3-Exit to return to the System Processing Menu.
|