MAC-PAC Homecontact ussupport login 
Documentation > MAC-PAC Reference and Help > Reference File Categories > SYNCHRO PARAMETERS

Function Select

RFG19S01 - Function Select
WILLIAMS                       COMMON FEATURES                         2/14/92

 DSP01                    REFERENCE FILE CATEGORY G19           FUNCTION SELECT

                                                                                

                                                                               

                   Category Name           SYNCHRO PARAMETERS                  

                                                                               

                                                                               

                                        ONLY RECORD                            

                   Category Key                                                 

                                                                               

                                                                               

                                                                               

                   Request Code         4                                      

                                                                               

                                        1 - Add                                

                                        2 - Change                             

                                        3 - Delete                             

                                        4 - Inquire                            

                                                                               

                                                                               

                                                                               

 F2=Command          F3=Exit             F7=End Category     F8=Display List   

 F9=Inquiry                                                                    

                                                                               

 

 

The Synchro Control Parameters category defines default values used by programs throughout the Synchro module.

This category is optional, and contains only one record.

Detail

RFG19S02 - Detail
 WILLIAMS                       COMMON FEATURES                         9/22/95

 DSP01                    REFERENCE FILE CATEGORY G19                   INQUIRE

                                                                                

                   Category Name           SYNCHRO PARAMETERS                  

                                                                               

                                        BLANK KEY                              

                   Category Key                                                

                                                                               

                                                                                

            DEN.CNV.FACT.FLG(0/1) MIN DAYS MNTLY PER/RLS PRE-PRT/SL(1/0)       

       Data 1                     28                     0                     

            X                     XX                     X                     

                                                                               

            NO OF KEPT ENDORS   NO OF MTH/ENDORS.  NO OF MTH/D.R.              

       Data 02                  05                 01                           

            XX                  XX                 XX                          

                                                                               

            NO OF MTH/SHIP.PROP.  NO OF MTH EXCEPT.DATES LABLS SAV PERD.       

       Data 01                    01                     00                    

            XX                    XX                     XX                    

                                                                               

 F2=Command          F3=Exit             F9=Inquiry          F10=Function Select

                                                                               

                                                                               

 

 

This screen allows you to define the Synchro parameters.  After you define these parameters initially, they are display only.

DENOMINATOR CONVERSION FACTOR FLAG (0/1)

Required.  This is the denominator flag for the units of measure conversion factor:

0 - any denominator

1 - '1' denominator

NUMBER OF DAYS MONTHLY PERIOD/RELEASE

Optional.  The periods indicated within the delivery request releases must be, as per GALIA standards, of increasing length. However, in order to avoid potential problems with months of variable length (28, 29, 30 or 31 days), you can define a number of days after which no control is executed.  For example, you can enter '28' as being the shortest month.

PRE-PRINT OF SHIPPING LIST (0/1)

Required.  This is the pre-print flag for the shipping lists:

0 - Shipping lists are not pre-printed.

1 - Shipping lists are pre-printed.

NUMBER OF KEPT ENDORSEMENTS

Optional.  Indicates the number of endorsements kept by the item/delivery point relationship.  The default value is 02.

NUMBER OF MONTHS/ENDORSEMENT

Optional.  Indicates the minimum number of months required prior to purging an endorsement (of D or I status).  The default value is 01.

NUMBER OF MONTHS/DELIVERY REQUEST

Optional.  Indicates the minimum number of months required prior to purging a delivery request of closed status.  The default value is 01.

NUMBER OF MONTHS/SHIPPING PROPOSAL

Required.  Indicates the minimum number of months required prior to purging a shipping proposal.  The default value is 01.

NUMBER OF MONTHS EXCEPTION DATES

Required.  Indicates the minimum number of months required prior to purging an exception date.  The default value is 01.

LABELS SAVED PERIOD

Optional.  Indicates the minimum number of months required prior to purging labels that have not been shipped.