MAC-PAC Homecontact ussupport login 
Documentation > MAC-PAC Reference and Help > Reference File Categories > QUALITY STL STS CODES

Function Select

RF467S01 - Function Select

WILLIAMS                       COMMON FEATURES                         2/05/92

 DSP01                    REFERENCE FILE CATEGORY 467           FUNCTION SELECT

                                                                                

                                                                               

                   Category Name         QUALITY CTL STS CODES                 

                                                                               

                                                                               

                                        BLANK KEY                              

                   Category Key                                                 

                                                                               

                                                                               

                                                                               

                   Request Code         4                                      

                                                                               

                                        1 - Add                                

                                        2 - Change                             

                                        3 - Delete                             

                                        4 - Inquire                            

                                                                               

                                                                               

                                                                               

 F2=Command          F3=Exit             F7=End Category     F8=Display List   

 F9=Inquiry                                                                    

                                                                               

 

 

The Quality Control Status Codes category contains all the valid status codes used in the system.  The first five status codes are system defined.  In addition, two codes may be user defined.  If user defined codes are used, the system must be modified to process them.  This category is required if Purchasing is installed.

This category has a blank key to allow only one record.

Detail

RF467S02 - Detail

 WILLIAMS                       COMMON FEATURES                         2/05/92

 DSP01                    REFERENCE FILE CATEGORY 467                   INQUIRE

                                                                                

                   Category Name         QUALITY CTL STS CODES                 

                                                                               

                                        BLANK KEY                              

                   Category Key                                                

                                                                               

                                                                                

            QUALITY CONTROL STATUS CODES:                                      

       Data NWIAC                                                              

            XXXXXXX                                                            

                                                                               

            DECODES:   NO CONTROL    WAITING CONTROL    CTL-IN-PROCESS         

       Data               NOC              WAI                CIP               

                          TTT              TTT                TTT              

                                                                               

            WAITING INVENTORY ADJUSTMENT  COMPLETE  USER-DEFINED DECODES       

       Data             ADJ                  COM                               

                        TTT                  TTT         TTT     TTT           

                                                                               

 F2=Command          F3=Exit             F9=Inquiry          F10=Function Select

                                                                               

                                                                               

 

 

This screen is used to define the default Quality Control status codes.

QUALITY CONTROL STATUS CODES

Required.  Used to define the quality control status codes that can be used in the system.  Each code is one character.  The first five codes (N.W.I.A.C.) are system defined. The remaining codes may be used defined and the system must be modified to process them.

NO CONTROL

Required.  Used to define the No Control status decode.

WAITING CONTROL

Required.  Used to define the Waiting Control status decode.

CTL-IN-PROCESS

Required.  Used to define the Quality Control in Process status decode.

WAITING INVENTORY ADJUST

Required.  Used to define the Waiting for Inventory Adjustment status decode.

COMPLETE

Required.  Used to define the Complete status decode.

USER DEFINED CODES

Optional.  Used to define the user defined status decodes.