MAC-PAC Homecontact ussupport login 
Documentation > MAC-PAC Reference and Help > Reference File Categories > MFG MONITOR DESCRIPTION

Function Select

RFN36S01 - Function Select
 WILLIAMS                       COMMON FEATURES                         3/31/97

 DSP01                    REFERENCE FILE CATEGORY N36           FUNCTION SELECT

                                                                               

                                                                               

                   Category Name        MFG MONITOR DESCRIPTION                

                                                                               

                                                                               

                                        BLANK KEY                               

                   Category Key                                                

                                                                               

                                                                               

                                                                               

                   Request Code         4                                      

                                                                               

                                        1 - Add                                

                                        2 - Change                             

                                        3 - Delete                             

                                        4 - Inquire                            

                                                                               

                                                                               

                                                                                

 F2=Command          F3=Exit             F7=End Category     F8=Display List   

 F9=Inquiry                                                                    

 

The Manufacturing Monitor Description category allows you to define the number of manufacturing monitors you would like to use.  If only one is specified, only MPASYNCMON will be used.  You will also be able to define the description of the four monitors that will be displayed on the Initiate/Cancel Monitors screen.

The Initiate/Cancel Monitors screen will allow you to cancel and initiate the manufacturing monitors you wish to use and only the monitors defined on this reference file category will be displayed on the screen.

This category has a blank key to allow only one record.

Detail

RFN36S02 - Detail
 WILLIAMS                       COMMON FEATURES                         3/31/97

 DSP01                    REFERENCE FILE CATEGORY N36                   INQUIRE

                                                                               

                   Category Name        MFG MONITOR DESCRIPTION                

                                                                               

                                        BLANK KEY                              

                   Category Key                                                

                                                                               

                                                                                

            DESCRIPTION MONITOR 1         DESCRIPTION MONITOR 2                

       Data Main Manufacturing MSQ        MON2:MSGQ for Bar-Code               

            XXXXXXXXXXXXXXXXXXXXXX        XXXXXXXXXXXXXXXXXXXXXX               

                                                                               

            DESCRIPTION MONITOR 3         DESCRIPTION MONITOR 4                

       Data MON3:MOMNT; LR's; CR's        MON4: Overflow                       

            XXXXXXXXXXXXXXXXXXXXXX        XXXXXXXXXXXXXXXXXXXXXX               

                                                                               

                                                                               

       Data                                                                    

                                                                               

                                                                                

 F2=Command          F3=Exit             F9=Inquiry          F10=Function Select

                                                                               

 

 

This screen allows you to define the description of the three monitors to be displayed on the Initiate/Cancel screen, in addition to the main manufacturing monitor, MPASYNCMON.

DESCRIPTION MONITOR 1

Optional; at least one monitor description must be entered and it must be unique.  Enter the description to be used for the MPASYNCMON.

DESCRIPTION MONITOR 2

Optional; at least one monitor description must be entered and it must be unique.  Enter the description for the additional manufacturing monitor 2.

DESCRIPTION MONITOR 3

Optional; at least one monitor description must be entered and it must be unique.  Enter the description for the additional manufacturing monitor 3.

DESCRIPTION MONITOR 4

Optional; at least one monitor description must be entered and it must be unique.  Enter the description for the additional manufacturing monitor 4.