Function Select

RF030S02 - Detail

 WILLIAMS                       COMMON FEATURES                         6/25/94

 DSP01                    REFERENCE FILE CATEGORY 030                  ADDITION

                                                                                

                   Category Name        Window Indicators                      

                                                                               

                                        Field Set/ Indicator                   

                   Category Key         SOLINE  WN                             

                                                                               

                                                                                

                   Description                                                 

       Data SALES ORDER LINE DEFAULT                                           

            TTTTTTTTTTTTTTTTTTTTTTTTT                                          

                                                                               

                                                                               

       Data                                                                     

                                                                               

                                                                               

                                                                               

       Data                                                                    

                                                                               

                                                                               

 F2=Command          F3=Exit             F9=Inquiry          F10=Function Select

 F12=Lower Case      F15=Rekey Data                                            

                                                                               

 

 

This screen allows you to maintain a description for the field set/window indicator combination you entered on the Function Select screen.

DESCRIPTION

Required.  Enter a description for the specified field set/window indicator combination.  This description will appear when F8=List is pressed from the Function Select screen on this category and category 031 - Field Sets.

Detail

RF031S02 - Detail

 WILLIAMS                       COMMON FEATURES                         5/26/94

 DSP01                    REFERENCE FILE CATEGORY 031                   INQUIRE

                                                                                

                   Category Name        Field Sets                             

                                                                               

                                        Field Set                              

                   Category Key         SOLINE                                 

                                                                               

                                                                                

                 Field Set Description                   Alt Set (Y/N)         

       Data Sales Order Line Maintenance                       N               

            TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT           Y               

                                                                               

            Parent Set Name           50-char Field Text     Help Tag          

       Data                            Config Code            CZCFGC            

                XXXXXXXX               TTTTTTTTTTTTTTT        XXXXXX           

                                                                               

            VV Program Name                                                    

       Data   VVEC140MW                                                        

              XXXXXXXXXX                                                       

                                                                               

 F2=Command          F3=Exit             F9=Inquiry          F10=Function Select

                                                                               

                                                                               

 

 

This screen allows you to maintain specific information for the field set specified on the function select screen.

DEISPLAY LIST DESCRIPTION

Required.  Enter a description for the list.  This description will appear when F4=Prompt is pressed from the field list field in maintenance conversation.

ALTERNATE FIELD SET (Y/N)

Optional.  If this field set is associated with another field set (i.e., will be referenced by another field set in Reference File category 032), enter a Y-Yes in this field.  Otherwise, enter a N-No in this field.  This field is only used for advanced, administrative maintenance tasks.

PARENT FIELD SET

Optional.  This field must contain a valid field set from Reference File category 031.  If the field set you are currently maintaining has a parent field set, that parent list must be entered here.  This field is only used for advanced, administrative maintenance tasks.

50-CHARACTER FIELD TEXT

Optional.  Enter a description for the 50-character field that can appear on each window.  This field is typically the Expert Configurator's configuration code; it appears depending on the value of the Display 50-character Field flag on Reference File category 032  Window Action Codes.  If your window does not have an associated 50-character field, leave this field blank.

HELP TAG

Optional.  Enter a help tag for the 50-character field that can appear on each window.  This field is typically the Expert Configurator's configuration code; it appears depending on the value of the Display 50-character Field flag on Reference File category 032 - Window Action Codes.

VV PROGRAM NAME

Optional.  Enter a valid values program to call when the 50-character field that can appear on each window is prompted using F4=Prompt.  This field is typically the Expert Configurator's configuration code; it appears depending on the value of the Display 50-character Field flag on Reference File category 032 - Window Action Codes.