MAC-PAC Homecontact ussupport login 
Documentation > MAC-PAC Reference Library > Manufacturing > Just-in-Time > Screens > Part/Production Center Relationship > JT160S01 - Function Select

JT160S01 - Function Select

 

 

WILLIAMS   PLT BEL               JUST-IN-TIME                          2/19/95

 DSP01               PART/CENTER RELATIONSHIP MAINTENANCE       FUNCTION SELECT

                                                                               

                                                                               

                                                                               

              Part Number        PHD-12                                         

                                                                               

              Production Center  CELL2                                         

                                                                               

                                                                               

              Maintenance Code   1                                            

                                                                               

                                                                                

                                 1 - Add A Relationship                        

                                 2 - Change A Relationship                     

                                 3 - Delete A Relationship                     

                                                                               

                                                                               

                                                                                

                                                                               

                                                                               

 F3=Exit             F4=Prompt           F7=P/M Maintenance  F8=P/M Inquiry    

 F11=P/C Maintenance F12=P/C Inquiry     F17=New Plant       F24=More Keys     

 

This screen is used to define productivity information for a part which is created in a particular production center.  This information should be defined for every production center in which a JIT part is manufactured using Just-In-Time manufacturing techniques.  A default part/production center relationship is automatically created by the Part Master Maintenance conversation when primary production center for a part is defined.  This primary production center is the center in which flow schedules and flow requirements are automatically created by the MS and RP Planning modules.  Production can be smoothed over several production centers by decreasing production in the primary production center and rescheduling or "adding it" into the secondary production centers for the part defined by these part/ production center relationships.  Flow schedules and flow requirements generated in secondary production centers are added as firmed production, and as a result MS and RP will not adjust these production records.

PLANT

Required.  Used to identify the plant in which maintenance/inquiry will be done.  The plant must be valid, and you must be authorized to the manufacturing company/warehouse associated with the plant (Reference File Category 409).  Defaults to the plant assigned to your user ID, but may be changed by pressing F17.

PART NUMBER

Required.  Enter the part number for which the part/production center relationship will be established.  The part must be a valid part in the given plant and have a production type of 2 (JIT) on the Part Master File.

PRODUCTION CENTER

Required.  Enter the production center for which the part/production center relationship will be established.  The production center must be a valid and defined in the given plant.

MAINTENANCE CODE

Required.  Must be one of the maintenance codes (1, 2, or 3) listed on the screen.

COMMAND KEYS

Enter - Process the request.

F2    - Display a window where a fast path option or mnemonic can be entered.  Fast path allows the next menu selection to be made directly from this screen.  When the window is displayed, pressing F3 will remove it.

F3    - Exit the program and return to the menu.

F4    - Display a list of values for the field where the cursor is positioned.  If you select one of the items from the list, it will be returned to the application screen.

F7    - Allows the user to fast path to the Part Master Maintenance conversation with the part number present on the Function Select screen.  Changes to the default part/production default part/production center (primary relationship) must be made on the Part Master - Change Productivity Screen since this conversation does not update the Part Master File.

F8    - Allows the user to call the Part Master Inquiry program directly to review information associated with the primary part/production relationship.

F9    - Enter the Part/Production Center Relationship Inquiry program with the part and production center from this screen.

F11   - Allows the user to fast path to the Production Center Maintenance program with the production center from this screen.

F12   - Allows the user to call the Production Center Inquiry directly with the production center on this screen.

F17   - Used to change the plant in which the user is working.

F24 -   Display additional command keys available from this screen.