WILLIAMS   PLT BEL                BILL OF MATERIAL                     3/03/93

 DSP01                          SINGLE LEVEL EXPLOSION                   SELECT

                                                                               

                                                                               

                                                                               

                                                                               

                       Part Number       BIKETIRE                              

                                                                               

                       Display Comments  N                                     

                                                                               

                       Effectivity Date  030393                                

                                                                               

                                  -or-                                          

                                                                               

                       Revision Level                                          

                                                                               

                                                                               

                                                                               

                                                                                

                                                                               

                                                                               

 F2=Command          F3=Exit             F4=Prompt           F9=Maintenance    

 F17=New Plant                                                                 

                                                                                                                               

 

 

This screen is used to request a single-level bill of material explosion.  Valid part types which may have bills of material are manufacturing, build-thru, transfer planning, purchase, and raw material parts.

PLANT

Required.  Used to identify the plant where the workcenters exist.  The plant must be valid (not blanks or nines) and the user must be authorized to the manufacturing company/warehouse associated with the plant (Reference File Category 409).  Defaults to the plant are assigned to the user ID, but may be changed by pressing F17.

PART NUMBER

Required.  Must be an active manufactured, planning, build-thru, transfer, purchase, or raw material part with at least one component.

DISPLAY COMMENTS

Required.  Put a 'Y' in this field if you wish to view the BOM comments that accompany this product structure.  This field must be either a 'Y' or a 'N'.

EFFECTIVITY DATE

Required.  Only the components that are in effect on the requested date will be displayed.  If you wish to review all components, regardless of effectivity date, enter ALL.

REVISION LEVEL

Optional.  The version of the product structure that you want to view.

COMMAND KEYS

Enter - Display the detail screen.

F2    - Display a window where a fast path option or mnemonic can be entered.  Fast path allows the next menu selection to be made directly from this screen.  When the window is displayed, pressing F3 will remove it.

F3    - Exit program and return to menu.

F4    - Display a list of values for the field where the cursor is positioned.  If you select one of the items from the list, it will be returned to the application screen.

F9    - Enter the Product Structure Maintenance Program.

F17   - Used to change the plant in which the user is currently working.