MAC-PAC Homecontact ussupport login 
Documentation > MAC-PAC Reference Library > Distribution > Synchro > Screens > Synchro DELINS > GA215S01 - Function Select

GA215S01 - Function Select

 

 

WILLIAMS                           SYNCHRO                             3/10/93

 DSP01                        MESSAGES MAINTENANCE              FUNCTION SELECT

                                                                               

                                                                               

                                                                               

                                                                               

                      File                 1                                   

                                                                                

                                           1 - DELINS/VDA Del Req              

                                                                               

                                                                               

                                                                               

                      Message ID                                               

                                                                                

                      Sender EDI No                                            

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                                

 F2=Command          F3=Exit             F4=Prompt                             

                                                                               

                                                                               

 

 

DELINS/VDA are the electronically transmitted delivery requests sent to you from your customers.  If a request message contains an error, it is rejected and placed in the Erroneous DELINS/VDA File.  The DELINS/VDA Maintenance Function Select Screen (GA215S01) allows you to access rejected DELINS/VDA messages and maintain them.  This enables you to re-transmit the corrected messages.

You can request to display erroneous messages, and perform DELINS/VDA acquisition simulation to check the message's validity in real time, hold, release, delete or reactivate.  You can only perform acquisition simulation if you are authorized to accept partial DELINS on Reference File category G26 (Synchro Daily Batch Parameters).

FILE

Required.  Enter the message file type to be changed.  Currently, the only file you can enter is '1' - DELINS/VDA File.  The system will then display the list of the selected messages.

MESSAGE IDENTIFICATION NUMBER

Optional.  Allows you to display the list of messages from a given acquisition date, date/time, or message identification number (date/time/6 digit identification number).

SENDER EDI IDENTIFICATION NUMBER

Optional.  Allows you to display the list of messages for a given sender, assuming that the 'Sender' field is correctly entered in the files by the syntax translation program.

COMMAND KEYS

Enter - Validates the entered data and displays the detail screen.

F2    - Displays a window where a fast path option or mnemonic can be entered.  Fast path allows the next menu selection to be made directly from this screen.  When the window is displayed, pressing F3 will remove it.

F3    - Exits this screen without validating or updating the entered data.